Logo
  • Home
  • Services
    • New Construction Quality Assurance
      • Design & Submittal Review
      • Mock Up Evaluation
      • Construction Inspection
      • Conflict Resolution
      • Enclosure Commissioning
      • MEP Commissioning
    • Water Intrusion
      • Spray Testing
      • Pressurzied Chamber Testing
      • Sealants & Adhesives
      • Infrared Thermography
    • Air Leakage
      • Whole Building Air Leakage Test
      • USACE Protocol
      • Component & Chamber Testing
      • Infrared Thermography
    • Energy Evaluation
    • Laboratory Testing
  • Experience
  • Corporate Info
    • About Us
    • Hiring
    • Leadership
    • Why Choose Us?
  • Contact Us
Enclosure Quality Assurance at Gables Tanglewood in Houston by Blue Quality Services
Enclosure Quality Assurance at Gables Tanglewood in Houston by Blue Quality Services
Enclosure Quality Assurance at Gables Tanglewood in Houston by Blue Quality Services
Enclosure Quality Assurance at Gables Tanglewood in Houston by Blue Quality Services
envelope commissioning
envelope commissioning
envelope commissioning
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

The Cherry Creek Apartment Complex located in Denver, Colorado. The 8-story complex is comprised of 289 apartment homes and will house a top-floor pool deck, yoga studio, media room, dog wash area, and a bike repair shop. The owner requested Blue Quality Services provide our Building Enclosure Quality Assurance Program during the design and construction to verify that the building and all of its systems and assemblies are design, installed, and tested to meet the owners requirements.

The owner requested our services begin during the design phase with a detailed review of the enclosure assembly. Once the building wall, window, and roofing performance needs were identified, we reviewed the drawings, details, and specifications for potential issues, conformance with project requirements, and constructability concerns.

During the construction phase, our field services team visits the site twice weekly to verify that the installation of the building enclosure systems are meeting project specifications. Our team follows up each visit with a field report, outlining both conformance and non-conformance issues. This report is sent to all involved stakeholders to keep everyone abreast of construction progress and flag any issues to be resolved. An issues list has been maintained throughout the project, detailing the observed issues, the date observed, a photo of the issue, a description of the resolution, and the issue’s resolution date.

Our field services team also performed pressurized chamber testing on operable windows, patio doors, and sliding doors in accordance with ASTM E 783.02 and ASTM E 1105. All test findings were described in our reports we sent to all members of the project team immediately after the testing is complete. Our same day reports help to provide quick feedback regarding the installation quality, alert the project team early of any leakage, and prevents systemic problems.

Related Project Experience

Blue Quality Services
Blue Quality Services
Blue Quality Services
Blue Quality Services
Blue Quality Services
Blue Quality Services
Blue Quality Services

Gables Cherry Creek
Denver, Colorado

8-Story, 289 Units

Services:
    Field Quality Inspections during Construction
    Enclosure Design Review
    Issues Resolution Tracking
    Water Spray Testing
    Pressurized Chamber Testing

Back to Project Experience

HOME
SERVICES
EXPERIENCE
CORPORATE INFO
CONTACT US


Copyright 2016 Blue Quality Services

CONTACT INFORMATION
611 WEST 22ND STREET, NO. 207
HOUSTON, TEXAS 77008


PHONE: 877.986.BLUE
EMAIL: INFO@BLUEQS.COM

Demand Quality.